OUR INSPECTION PROCEDURES EXCEED MIL-SPEC AND THAT OF MOST MAJOR SUPPLIERS
Inspections are performed throughout the production process by the machine operators and by inspectors on the plant floor. Instruments are calibrated and we have a large selection of measurement equipment. In the inspection room we have an Optical Comparator, Rockwell Hardness Tester, Coordinate Measuring Machine, and a full assortment of Jo blocks, surface plates, intrimiks, micrometers, height gauges, plug gauges, thread gauges & verniers. The CMM is capable of producing printed reports, and utilizes Reflex Software for integration to the Cad/Cam system. A full Quality Control Manual is available for review. Quality Assurance based on Mil-I- 45208A
|
HIGH QUALITY PRECISION MACHINE PARTS
|
BROWN & SHARPE - Gage 2000
Coordinate Measuring Machine
With on board computer and printer.
Jones & Lamson Optical Comparator
|
Non-destructive testing.
Penetrant inspection is to be done on non-ferrous alloys (non-magnetic) such as aluminum, 300 series stainless,
titanium, inconel and so on. The fluorescent liquid penetrates deep into any defects open to the surface and are
highly visible when viewed under a black light. This will occur with discontinuities such as porosity hair-line cracks
and similar defects.
Radiography Testing
It has the capability of finding defects and flaws throughout an entire part. This is one of the most effective ways of
determining soundness. Radiography can be used for welder certifications, proving soundness of castings and
more.
Magnetic Particle Testing
Magnetic particle inspection is completed on ferrous (magnetic) materials such as carbon steel or 420 stainless
steel. Linear and longitudinal indications are viewed under the black light, which reveals both surface and some sub-
surface defects.
Fluorescent Penetrant Testing
Penetrant inspection is to be done on non-ferrous alloys (non-magnetic) such as aluminum, 300 series stainless,
titanium, inconel and so on. The fluorescent liquid penetrates deep into any defects open to the surface and are
highly visible when viewed under a black light. This will occur with discontinuities such as porosity hair-line cracks
and similar defects.
Testing performed by Nadcap certified vendor.
100% quality rating for over 35 years, Winner of numerous awards- Pitney Bowes, Inc.
Registered Government Contractor Cage: 4VU85
|